Shape the future of IBM!
We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:
Post your ideas
IBM is transforming its request for enhancement (RFE) process. The purpose of the transformation is to provide a more consistent experience for you to submit requests and to enable IBM product owners to respond to your requests more quickly. For more information click here.
Start by posting ideas and requests to enhance a product or service. Take a look at ideas others have posted and upvote them if they matter to you,
1. Post an idea
2. Upvote ideas that matter most to you
3. Get feedback from the IBM team to refine your idea
Help IBM prioritize your ideas and requests
The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The offering manager team will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.
Receive notifications on the decision
Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.
-
Map report in design server
In Desing studio we have this option to create a map report, Map->generate report. Can we have something like that in desing server version to generate report of the mapping component?
-
Transformation Extender to provide Map Coverage in a similar way Sonar provides code coverage.
We would like to have a tool, similar to the code coverage tools that they have for traditional code, available for ITX maps.
Requirements:
This functionality must be invokable both through the graphical map design tooling and available ...
-
PGP Adapter : Enable support for different Encryption , Signing & Compression Algorithm
The OpenPGP adapter does not support all of the latest set of Encryption , Signing & Compression Algorithm natively. Below are the list of supported values Compression types (-COMALG) : ZLIB Encryption Algorithm (-ENCALG ) : 3DES , RIJNDAEL256...
-
DTXDS APIs for the Launcher
We are currently trying to automate a bit our software lifecycle management and we would like to automate the compilation and deployment of maps on our Linux system. We are using Azure pipeline for this automatization and we would like to have a w...
-
The ITX mapper needs to be capable of supporting Sterling B2Bi Envelope/Control Number management is a similar manner to how it support ITXA in order to fully leverage ITX maps within the Sterling B2Bi product
This ask effectively is to expand the Sterling Data Harness called within ITX maps to support more than just delimited from the Sterling Envelope but allow for a get & increment control number(s) as well as all sender/receiver/qualifer/version...
-
Transaction reports
We have upgrading the Partner Manger to ITXA and Presently in the Trading manager we have option to see the transaction report( see attached transaction report for details) we are looking not exact similar functionality but want to check if their ...
-
Override CURRENTDATETIME value by run parameter
Our team wants to build automatic regression tests for continous integration and simplifying release changes. Also the tests would be repeatable. The outputs in between two runs are different if the output contains an CURRENTDATETIME function. We ...
-
ITXA : Fix the migration of envelopes from Sterling B2B Integrator and ITXA
When we export envelope from SI and import to ITXA, we are missing some configuration. Please see the word document attached.
-
ITXA - Create 999 when there an error in the ST segment
Create 999 when there an error in the ST segment. Currently when there is an error in ST segment, transactions are not processed further and information required for 999 ACK generation is not passed. This creates a scenario where there is not vali...
-
WTX/ITX Oracle adapter - automatic failover implementation
We are using the WTX/ITX Oracle adapter for our connection with an Oracle Exadata database.
In case of database failure, Exadate switch automaticly to the second cluster node.
>> Problem :
At the switch time, all running maps faile w...
By clicking the "Post Comment" or "Submit Idea" button, you are agreeing to the IBM Ideas Portal Terms of Use.
Do not place IBM confidential, company confidential, or personal information into any field.