Skip to Main Content
IBM Sterling


This portal is to open public enhancement requests for IBM Sterling products and services. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Sterling Connect:Direct for Z/OS

Showing 30

Provide Usermod or disable DGAXTABL by default

After installing PTFs UI91208, UI90597 we began having failures with transmissions which we later identified as DGAXTABL being introduced. PTF UI91208 had no hold information about updating DGAXTABL exit requirement whatsoever, and UI90597 had an ...
over 1 year ago in Sterling Connect:Direct for Z/OS 5 Delivered

Include active MAXUSERS in high water mark SMF record

Highwater mark SMF record should include Active MAXUSERS to have full pictures of how region is performing. We've experienced BTL issues relating to high MAXUSERS counts and we don't have accurate insight into how many users are active at that time.
over 2 years ago in Sterling Connect:Direct for Z/OS 2 Delivered

Improve diagnostic accuracy of Secure+ error messages

We often get Secure+ error messages (prefix CSPA) that don’t necessarily indicate a Secure+ issue. This makes it difficult to monitor for errors. The error messages that have caused us the most difficulty are: CSPA202E SSL handshake failure, re...
over 6 years ago in Sterling Connect:Direct for Z/OS 5 Delivered

Provide control over who can use the SNODEID parameter

With SPOE, the SNODEID presents a security vulnerability. The SNODEID is hard-coded in the process in clear text. Anyone authorized to use CDZ and able to read the file where the SNODEID is coded, typically in the process library, can create and s...
over 6 years ago in Sterling Connect:Direct for Z/OS 4 Delivered

Wildcards to send PDS datasets to Linux/Windows directories

Actually it's not possible to send PDS members from CDzOS to CDLinux or CDWindows, using wildcards, f.i. USER.PDS.DSN(*) to /user/path/*. We have several applications that are using other products like XCOM or MQFTE, and with these products it's p...
about 1 year ago in Sterling Connect:Direct for Z/OS 5 Delivered

In CDPLEX environment, CD manager needs to issue a message to indicate server is down after receiving XCF signal

In case TS009569597, we have found CD manager hangs at shutdown due to shutdown has been initiated for CD manager but XCF signal for CD server down has not been received by CD manager.
over 2 years ago in Sterling Connect:Direct for Z/OS 3 Delivered

Can Secure+ be made any simpler?

I spend a lot of time trying to figure out Secure+ screens. Is there any way they could add more help to PF1?
over 6 years ago in Sterling Connect:Direct for Z/OS 2 Delivered

Issue a message when CDz reached NODE Specific Max PARSESS Limit

CDz does issue SVTM082I when CDz as node hit the node specific SESS.SNODE.MAX. However, it doesn't issue any message when it reached Max PARSESS. Could you add a corresponding message for this so that we can easily figure out it hit the limit? It ...
over 6 years ago in Sterling Connect:Direct for Z/OS 4 Delivered

Extensions to Compress with Connect:Direct

Our clients who are transferring from Connect:Direct are using windows.However, because of the smaller lrecl of the file being transferred, it will not be compressed for the following third specification: 1) CD z/OS to CD z/OS transfer will be in ...
about 6 years ago in Sterling Connect:Direct for Z/OS 2 Delivered

Provide additional information when Session High Water Mark is reached

For Product id 5665-X09, record the number of active PRIMARY (PNODE) sessions and the number of active SECONDARY (SNODE) sessions when the session high water mark is reached. Record as much additional information as is reasonably possible in the s...
almost 7 years ago in Sterling Connect:Direct for Z/OS 1 Delivered