Skip to Main Content
ADD A NEW IDEA

Sterling Connect:Direct for Z/OS

Showing 60

Target node alternate communication paths not retried when connected via Sterling Secure Proxy.

There appears to be a design flow within CD/Z when communicating via SSP and target CD node not being reachable via primary path, CD/Z initial SSL handshake times out and connection to target CD node not retried by CD/Z via ALT.COMM path(s).
7 months ago in Sterling Connect:Direct for Z/OS 9 Future consideration

Connect:Direct RESTAPI at the CD nodes (including Z) support

We would like be able to use RESTAPI services to access Connect:Direct at the z/OS node level (not via CDWS) in order to handle job abends with NDM status
7 months ago in Sterling Connect:Direct for Z/OS 8 Functionality already exists

Dynamic removal of redundant checkpoint entries

Can the logic behind CKPT.DAYS be extended so that this function in invoked on a regular basis (e.g. daily) instead of only when z/OS Connect:Direct is started? When the checkpoint dataset becomes full, the only way to defragment it or clear out r...
6 months ago in Sterling Connect:Direct for Z/OS 2 Future consideration

Include active MAXUSERS in high water mark SMF record

Highwater mark SMF record should include Active MAXUSERS to have full pictures of how region is performing. We've experienced BTL issues relating to high MAXUSERS counts and we don't have accurate insight into how many users are active at that time.
over 2 years ago in Sterling Connect:Direct for Z/OS 1

Security Exit must be usable by different SFTs and the STCname should be part of the RACF profile namess

In our environment we run several Connect:Direct stc's in one environment. The provided Security Exits do not offer a possibility to setup separate profiles for these stc's.We would like this to be changed. Second what we ask for is to add the STC...
about 3 years ago in Sterling Connect:Direct for Z/OS 2 Not under consideration

Allow PROPGATE.DSNTYPE=YES to work while PROPAGATE.SMSCLASS=(COND or YES,NO,NO) for PDSEs

Why is it useful? It will respect the source dataset’s DSNTYPE and allocate the dataset with the correct DSNTYPE. Who would benefit from it? Any z/OS platform that has ACS routines that do not override a user’s requested DSNTYPE. How should it wor...
3 months ago in Sterling Connect:Direct for Z/OS 1 Under review

For Type records panel to add confirmation prompt to confirm saving or record should not get added with PF3

Currently, there is delimitation while we go to admin panel for adding new type record in NDM admin-> IT panel , if we bychance hit PF3 it creates an incomplete record. And to remediate this everytime either we have to update the wrongly create...
3 months ago in Sterling Connect:Direct for Z/OS 2 Not under consideration

Generate longfile name for Connect:Direct transfers in log

We want to utilize transfer logs generated in syslog/task log to do some automation reporting and alerting. However NDM longfile name which reported in SMF type FI isn't written to syslog so we can't get full pictures for file transfers between un...
about 1 year ago in Sterling Connect:Direct for Z/OS 1 Functionality already exists

Enable connection pooling for remote nodes when using CDPLEX

We use the PARSESS ADJACENT.NODE statement to limit parallel sessions from the local node to a remote node based on capacity as agreed with the partner node. When updating our environment to use CDPLEX with multiple server regions, this parameter ...
almost 2 years ago in Sterling Connect:Direct for Z/OS 2 Not under consideration

Wildcards to send PDS datasets to Linux/Windows directories

Actually it's not possible to send PDS members from CDzOS to CDLinux or CDWindows, using wildcards, f.i. USER.PDS.DSN(*) to /user/path/*. We have several applications that are using other products like XCOM or MQFTE, and with these products it's p...
10 months ago in Sterling Connect:Direct for Z/OS 4