Skip to Main Content
ADD A NEW IDEA

WTX Compliance Checking

Showing 11

ITX 277CA Processing

Allow for detection of syntactical error in claim by STC0101, and also including an Entity code so that resultant 277CA is valid per use of the STC0102 value of 19: At each HL level in the 277, there could be rejected claim(s) due to invalid synta...

Allow ITX to handle Protobuf schemas

ITX currently can support AVRO schemas however there are other schemas that may be used depending on circumstances. One of these is the protobuf schema. Can this be added to the suite of schemas supported by ITX?
10 months ago in Sterling Transformation Extender / WTX Compliance Checking 1 Not under consideration

Compliance map not generating valid XML message on edi_log.xml

edi_log.xml generated output compliance maps are not valid XML for both EDIFACT and X12. They are missing closing tag for EDIFACT & root opening/closing tags for X12.

Including 277DRA transaction in Compliance Check

Our clients are seeking to check compliance on 277DRA transactions as well . Version - 5010

Bypass SNIP 3 and 4 to Allow Denied Claims to Flow Through

We have a client use case where we need to relax validations in order to allow denied claims to flow through that requires us to validate on SNIP 1, 2 and 7 (i.e. bypass SNIP 3 and 4). This is because denied claims might fail on SNIP 3 and 4 and h...

Alter The Transformation Extender Error Reject Report To Have An XML Format Similar To B2Bi

We currently running SI B2Bi v 6.1 and also have ITX 10.1.1 installed. ITX running with launcher on our AIX file system which works with BP's in SI B2Bi. We are requesting that the failures coming out of ITX be in the B2Bi XML Trans Report format ...
about 2 years ago in Sterling Transformation Extender / WTX Compliance Checking 1 Not under consideration

Include ISA information in either the data passed to the hcsvu exit for implementing a type 7 rule in the qualifier file or in the data passed to a type 7 custom user exit

We currently have a requirement to compare one of ISA value to 1000A NM1 values to ensure they are same and it is currently no doable in ITX. We received this as a suggestion from support ticket TS005672303
about 3 years ago in Sterling Transformation Extender / WTX Compliance Checking 0 Not under consideration

Compliance Check map to include the CTX segments in the 999 Negative Acknowledgement

the usage of the CTX segment in the 999 would utilized in the LOOP ID - 2100 - AK2/IK3 ERROR IDENTIFICATION. where the Business Unit Identifier can correctly show the transaction error. TR3 rules state "Required when the error reported in this IK3...
over 5 years ago in Sterling Transformation Extender / WTX Compliance Checking 5 Not under consideration

Utility to check compatibility and compliance of maps when upgrading to a new ITX version

ITX to provide an utility that can check if th existing maps are compatible with the new version of ITX or needs recompilation/modification. For shops with hundreds of maps this will identify the maps that need some action, hence improving the mig...
almost 4 years ago in Sterling Transformation Extender / WTX Compliance Checking 1 Functionality already exists

We need a Tool to Identify the Cause of HIPAA X12 Compliance Exceptions

Tool to Identify the Cause of HIPAA X12 Compliance Exceptions NASCO routinely receives very large HIPAA X12 transmissions from their business / trading partners. (Very large meaning millions of segments and tens of thousands of transactions.) Only...
almost 6 years ago in Sterling Transformation Extender / WTX Compliance Checking 1 Not under consideration